Bosch Rexroth AG, RE 18301-36/01.2025
2 EDH | 4/3 and 4/2 Proportional directional valve elements
Ordering details
Ordering details
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18
EDH-P-_-_-0-_ __ _ _ _ -_ _ _ _-_ _-_ _ _ _-_-_-_ _-_
Family
00 Directional Valve elements EDH Size 10 proportional EDH
Type
01 Electro - Piloted P
Flange (defi ne the following directional valve)
02 EDH H
EDG G
1)
Ports & Connections
03 G 1/2 DIN 3852 4
7/8-14 UNF (SAE10) D
Local compensator bias spring
04 8 bar (116 psi) 0
Hydraulic connections in neutral
05 P, A, B closed LS to T B
P closed A, B, LS to T E
Spool variants
06 4/3 operated both sides a and b 2
4/2 operated sides a 3
4/2 operated sides b 4
Flow rates over valve connection (according to table 1)
07 Flow rate P>A -
Flow rate P>B -
Nominal fl ow rate (A>T) -
Nominal fl ow rate (B>T) -
Voltage supply 01 03 07
08 12V DC ● ● ● OB
24V DC ● ● ● OC
● = Available – = Not available
Electric connections
2)
09 With coils, with connection DIN EN 175301-803 01
2)
With coils, with connection vertical Amp - Junior 03
With coils, with connection DT04-4P 07
Secondary valve types
10 Without secondary valve 00
Double or single full relief valve with Anticavitation
(VMA) or anticavitation only (VUM) or plug
M0
4)
Double or single LS relief valve (VMGLS) or plug 0M
Combination of M0 and 0M options together MM
Secondary valve confi g. setting:
Full Relief or Anticavitation selection (according to table 2)
11 A>Ta setting @5lpm _
3)
12 B>Tb setting @5lpm _
3)
Secondary valve confi g. setting: LS Relief (VMGLS)
(according to table 3)
13 LSA>T setting range @1.5lpm _
14 LSB>T setting range @1.5lpm _
Auxiliary ports on LSA and LSB
15 Cavity not drilled / No option 0
Both LSA and LSB G 1/8 DIN 3852 1
Emergency lever
16 No option 0
Lever type manual override on A side – Horizontal H
6)
Lever type manual override on A side – Vertical V
6)
Prepared for lever type manual override
on A side – stroke limitator
X
1) For combined valve blocks EDH+EDG the last EDH section must be
selected with fl ange "G"
2) For mating connectors ordering code see data sheet RE 18325-90.
3) "0" option is the only one available for "without secondary valves"
selection.
4) For fi xed setting relief valve data sheet see Data Sheet RE 18329-12.
For anticavitation valve data sheet see Data Sheet RE 18329-52.
5) For pressure rating selection refer to table 4.
6) The Spool Sensor option is not available in combination with the
emergency lever.
7) Electric connection of LS signal management cartridge valve in
accordance with fi eld "09".
LS signal management
7)
17 No option 00
LS cut-off - 2/2 cartridge valve normally open KKDER8 P
rif. RE18136-08
NO
LS cut-off - 2/2 cartridge valve normally closed KKDER8 N
rif. RE18136-08
NC
LS pressure control - Proportional pressure relief valve,
increasing characteristic curve KBPS.8A rif. RE18139-04
A_
5)
LS pressure control - Proportional pressure relief valve,
decreasing characteristic curve KBPS.8B rif. RE18139-05
B_
5)
Spool sensor
18 No option 0
Spool sensor on side "A" S
6)